SCSI External Centronics 50 (Differential)
From HwB
Pinout
50 PIN CENTRONICS FEMALE at the controller & devices.
50 PIN CENTRONICS MALE at the cable.
| Pin | Name | Dir | Description |
|---|---|---|---|
| 01 | GND | |
Ground |
| 02 | +DB0 | |
+Data Bus 0 |
| 03 | +DB1 | |
+Data Bus 1 |
| 04 | +DB2 | |
+Data Bus 2 |
| 05 | +DB3 | |
+Data Bus 3 |
| 06 | +DB4 | |
+Data Bus 4 |
| 07 | +DB5 | |
+Data Bus 5 |
| 08 | +DB6 | |
+Data Bus 6 |
| 09 | +DB7 | |
+Data Bus 7 |
| 10 | +DBP | |
+Data Bus Parity (odd Parity) |
| 11 | DIFFSENS | ? | ??? |
| 12 | res | - | Reserved |
| 13 | TERMPWR | |
Termination Power |
| 14 | res | - | Reserved |
| 15 | +ATN | |
+Attention |
| 16 | GND | |
Ground |
| 17 | +BSY | |
+Bus is busy |
| 18 | +ACK | |
+Acknowledge |
| 19 | +RST | |
+Reset |
| 20 | +MSG | |
+Message |
| 21 | +SEL | |
+Select |
| 22 | +C/D | |
+Control or Data |
| 23 | +REQ | |
+Request |
| 24 | +I/O | |
+In/Out |
| 25 | GND | |
Ground |
| 26 | GND | |
Ground |
| 27 | -DB0 | |
-Data Bus 0 |
| 28 | -DB1 | |
-Data Bus 1 |
| 29 | -DB2 | |
-Data Bus 2 |
| 30 | -DB3 | |
-Data Bus 3 |
| 31 | -DB4 | |
-Data Bus 4 |
| 32 | -DB5 | |
-Data Bus 5 |
| 33 | -DB6 | |
-Data Bus 6 |
| 34 | -DB7 | |
-Data Bus Parity7 |
| 35 | -DBP | |
-Data Bus Parity (odd Parity) |
| 36 | GND | |
Ground |
| 37 | res | - | Reserved |
| 38 | TERMPWR | |
Termination Power |
| 39 | res | - | Reserved |
| 40 | -ATN | |
-Attention |
| 41 | GND | |
Ground |
| 42 | -BSY | |
-Bus is busy |
| 43 | -ACK | |
-Acknowledge |
| 44 | -RST | |
-Reset |
| 45 | -MSG | |
-Message |
| 46 | -SEL | |
-Select |
| 47 | -C/D | |
-Control or Data |
| 48 | -REQ | |
-Request |
| 49 | -I/O | |
-In/Out |
| 50 | GND | |
Ground |
Note: Direction is Device relative Bus (other Devices).