SCSI Internal (Single-ended)
From HwB
SCSI=Small Computer System Interface
Based on an original design by Shugart Associates. SCSI was ratified in 1986.
[edit] Pinout
50 PIN IDC MALE at the controller & harddisk.
50 PIN IDC FEMALE at the cable.
| Pin | Name | Dir | Description |
|---|---|---|---|
| 2 | DB0 | | Data Bus 0 |
| 4 | DB1 | | Data Bus 1 |
| 6 | DB2 | | Data Bus 2 |
| 8 | DB3 | | Data Bus 3 |
| 10 | DB4 | | Data Bus 4 |
| 12 | DB5 | | Data Bus 5 |
| 14 | DB6 | | Data Bus 6 |
| 16 | DB7 | | Data Bus 7 |
| 18 | PARITY | | Data Parity (odd Parity) |
| 20 | GND | | Ground |
| 22 | GND | | Ground |
| 24 | GND | | Ground |
| 26 | TMPWR | | Termination Power |
| 28 | GND | | Ground |
| 30 | GND | | Ground |
| 32 | /ATN | | Attention |
| 34 | GND | | Ground |
| 36 | /BSY | | Busy |
| 38 | /ACK | | Acknowledge |
| 40 | /RST | | Reset |
| 42 | /MSG | | Message |
| 44 | /SEL | | Select |
| 46 | /C/D | | Control/Data |
| 48 | /REQ | | Request |
| 50 | /I/O | | Input/Output |
Note: Direction is Device relative Bus (other Devices).
All odd-numbered pins, except pin 25, are connected to ground. Pin 25 is left open.