SCSI-III External Hi D-Sub (Single-ended)
From HwB
[edit] Pinout
68 PIN HI-DENSITY D-SUB FEMALE at the controller & devices.
68 PIN HI-DENSITY D-SUB MALE at the cable.
| Pin | Name | Dir | Description |
|---|---|---|---|
| 1-16 | GND | | Ground |
| 17 | TERMPWR | | Termination Power |
| 18 | TERMPWR | | Termination Power |
| 19 | res | | reserved |
| 20-34 | GND | | Ground |
| 35 | DB12 | | Data Bus 12 |
| 36 | DB13 | | Data Bus 13 |
| 37 | DB14 | | Data Bus 14 |
| 38 | DB15 | | Data Bus 15 |
| 39 | DPB1 | | Data Parity (odd Parity) |
| 40 | DB0 | | Data Bus 0 |
| 41 | DB1 | | Data Bus 1 |
| 42 | DB2 | | Data Bus 2 |
| 43 | DB3 | | Data Bus 3 |
| 44 | DB4 | | Data Bus 4 |
| 45 | DB5 | | Data Bus 5 |
| 46 | DB6 | | Data Bus 6 |
| 47 | DB7 | | Data Bus 7 |
| 48 | DPB | | Data Parity (odd Parity) |
| 49 | GND | | Ground |
| 50 | GND | | Ground |
| 51 | TERMPWR | | Termination Power |
| 52 | TERMPWR | | Termination Power |
| 53 | res | | reserved |
| 54 | GND | | Ground |
| 55 | /ATN | | Attention |
| 56 | GND | | Ground |
| 57 | /BSY | | Busy |
| 58 | /ACK | | Acknowledge |
| 59 | /RST | | Reset |
| 60 | /MSG | | Message |
| 61 | /SEL | | Select |
| 62 | /C/D | | Control/Data |
| 63 | /REQ | | Request |
| 64 | /I/O | | Input/Output |
| 65 | DB8 | | Data Bus 8 |
| 66 | DB9 | | Data Bus 9 |
| 67 | DB10 | | Data Bus 10 |
| 68 | DB11 | | Data Bus 11 |
Note: Direction is Device relative Bus (other Devices).